Products Search
Name:XST Intelligent Digital Indicators
1.The Intrinsic Error is less than 0.2%F.S
2. It is adaptable to such signals as voltage, current, RTD, T/C, mV, Potentiometer, Pressure Gauges with Resistance Transmitter, etc.
3.An up to 8-point alarm output is available, which offers 10 selectable alarm types.
4.Re-Transmitted Output can be provided.
5.It has full-opened, high-speed, high-efficiency network communication interface
6.BCD code interface support
7.1″~ 12″large screen display is available
Description
1 2 3 4 5 6 7 8 9 10 11 12
XST / o—o o o T o A o B o S o V o o o o
Ø 1:Dimensions (W×H×L)
A:160×80×125 or 80×160×125
B:96×96×112
C:96×48×112 or 48×96×112
D:72×72×112
E:318×104×300 Panel Mounted or Desktop Use
Ø 2:Faceplate Types H:Horizontal Type
S:Vertical Type
F:Square Type
S:Vertical Type
F:Square Type
Ø 3:Display Types:
1:Measured Value(Green)
2:Measured Value(Green)+ Set Value(Red)
3:Measured Value(Green)+ Measured Value Light Bar(Green)
4:Measured Value(Green)+ Measured Value Light Bar(Green)+Set Value Light Bar(Red)
A-S Type only
A-S Type only
5:Measured Value(Green)+ Measured Value Light Bar(Green)+ Set Value(Red)
A-S Type only
A-S Type only
Y:LCD A-H Type & B Type only
★The color of LED is selectable according to order requirements.
Ø 4:Input Signal
E:Thermocouple or Radiation Thermometer
R:RTD or Resistance
I: DC Current
V:DC Voltage
M:mV
W:Potentiometer
L:Pressure Gauges with Resistance Transmitter
Ø 5:The Number of Alarm Outputs
T0:No Alarm
T1~T8:1~8 Alarm Outputs
C type limit: 3- Alarm Outputs
D type limit: 2- Alarm Outputs
B type limit: 4- Alarm Outputs
A type: when exceeding 4-points , 250mm in length
Ø 6:Re-Transmitted Output
A0:No Output
A1:DC Current Output(4 mA ~20 mA),(0 mA ~10 mA)or(0 mA ~20 mA)
A2:DC Voltage Output(0 V ~5 V), (1 V ~5 V)
A3:DC Voltage Output(0 V ~10 V)
A4:Other Outputs
Ø 7:Power Supply Output
B0:No
B1:24V DC
B2:12V DC
B3:Precise Constant Voltage Source
B4:Precise Constant Current Source
B5:Others
Ø 8:Communication Interface
S0:No
S1:RS 232
S2:RS 485
S3:RS 422
S4:BCD code(A, B type only)
Ø 9:Power Supply
V0:220V AC
V1:24V DC
V2:12V DC
V3:Others
Ø 10:Print Function:P(Print),N/A (without P)
(A, B type only)
(A, B type only)
Ø 11:Recording Unit:R(Recording Unit),N/A (without R)
(A, B type only)
(A, B type only)
Ø 12:N(Nonstandard Functions): Some parts of the instrument have been modified according to order requirements.